The voltmeter is connected across the resistor network. The ammeter is in series with it. Change the rheostat to change the current.
Connect
—
Current — · voltage —
The idea
For a metallic conductor at constant temperature the current is proportional to the potential difference across it (Ohm's law). The ratio V/I is the resistance R, and it does not depend on the current.
- Single resistor: V = I R, so R = V / I (slope of the V–I graph)
- In series: Rs = R₁ + R₂
- In parallel: 1/Rp = 1/R₁ + 1/R₂, or Rp = R₁R₂ / (R₁ + R₂)
Observations
—
| Rh (Ω) | I (A) | V (V) | R = V / I (Ω) |
|---|---|---|---|
| Mean R | — | ||
Check your readings
Summary of all four arrangements
| Arrangement | Readings | Measured R (Ω) | Expected (Ω) |
|---|
Graph
Plot V against I for the arrangement selected above. This is a straight line through the origin whose slope is R.
Take at least 2 readings to see the best-fit line.
Precautions
- Connect the ammeter in series and the voltmeter in parallel, with the positive terminals towards the positive of the cell.
- Check the zero error of both meters before starting.
- Keep the key closed only while taking a reading, so that the resistor does not heat up and change its resistance.
- Use the rheostat to keep the current small enough that the resistor does not become hot.
- Take readings with the needle well deflected, not near the zero of the scale, to reduce the percentage error.
- A real voltmeter draws a small current, so the measured resistance is very slightly less than the true value.