Plus Two Physics · Semiconductor Electronics

p-n junction diode: forward and reverse bias characteristics

Increase the voltage across a diode and read the current. In forward bias the current stays tiny until the knee voltage, then rises steeply. In reverse bias only a few microamperes flow. Find the knee voltage, the forward and reverse resistances, and tell whether the diode is silicon or germanium.

+ Battery Key K Rheostat (potential divider) Supply 0.00 V R = 100 Ω Milliammeter 0.0 mA Voltmeter V 0.000 V

Forward bias: the p side of the diode is connected to the positive terminal. The protective resistor limits the current.

Bias
—
—

The idea

A p-n junction has a depletion layer with a small potential barrier. In forward bias (p side to +) the applied voltage lowers the barrier. Very little current flows until the voltage reaches the barrier potential, the knee (cut-in) voltage: about 0.7 V for silicon and 0.3 V for germanium. Beyond it the current rises steeply. In reverse bias the barrier grows, and only a tiny reverse saturation current of minority carriers flows (nanoamperes for silicon, microamperes for germanium).

  • Knee voltage: extend the straight, steep part of the forward curve to meet the V axis
  • Forward (dynamic) resistance: rf = ΔV / ΔI on the steep part (a few ohms)
  • Reverse resistance: rr = ΔV / ΔI on the reverse curve (megaohms)

Observations

Forward bias

Sl.V (V)I (mA)

Reverse bias

Sl.V (V)I (µA)
Knee voltage—
Forward resistance—
Reverse resistance—

    Characteristic curve

    Forward readings are plotted in the first quadrant (mA) and reverse readings in the third quadrant (µA). The two quadrants use different scales, as in your record book.

    Take readings in forward and reverse bias to draw the curve.

    Precautions

    • Always use a protective resistor in forward bias, or the current can rise enough to damage the diode.
    • Use a milliammeter in forward bias and a microammeter in reverse bias. Check the polarity of the meters.
    • Near the knee the current changes quickly, so increase the voltage in small steps there.
    • Do not exceed the safe current in forward bias, and keep the reverse voltage well below the breakdown voltage.
    • Take readings with the key closed only for a short time, so that the diode does not heat up.