Tip: drag along the wire to get close, then use the slider and the −1 / −0.1 / +0.1 / +1 buttons for the final approach. The needle gets closer to zero as you near the balance point.
The idea
The wire has a uniform potential gradient k (volts per cm). At the null point the galvanometer reads zero, no current flows through the cell, and its emf equals the potential drop along the balance length.
- Cell E₁ connected: E₁ = k · l₁
- Cell E₂ connected: E₂ = k · l₂
- Dividing: E₁ / E₂ = l₁ / l₂
Changing the rheostat changes k, so both lengths change, but their ratio does not. That is why the experiment is repeated for several rheostat settings.
Observations
| Rh (Ω) | l₁ (cm) | l₂ (cm) | E₁/E₂ = l₁/l₂ |
|---|---|---|---|
| Mean E₁/E₂ | — | ||
Check your readings
Graph
Plot l₁ against l₂ for the completed sets. This is a straight line through the origin whose slope equals E₁/E₂.
Complete at least 2 sets to see the best-fit line.
Precautions
- Connect the positive terminals of the driver cell and of both test cells to the same end (A) of the wire.
- The driver cell's emf must be larger than the emf of either test cell, otherwise no balance point exists.
- Use the two-way key so that only one cell is connected to the galvanometer at a time.
- Keep the key closed only while taking a reading, so the cells do not run down.
- Do not slide the jockey along the wire; tap it at each position.
- Do not change the rheostat while the two lengths of one set are being measured.