Tip: drag along the wire to get close, then use the slider and the −1 / −0.1 / +0.1 / +1 buttons for the final approach. The needle gets closer to zero as you near the balance point.
Potential gradient — · wire drop —
Resistance box R
Key K₂
Open: cell on open circuit → measure l₁.
450.0 cm
Galvanometer
Deflection 0.0 div ·
The idea
The wire has a uniform potential gradient k (volts per cm). At the null point the galvanometer reads zero, so the potential across the length l equals the cell's voltage.
- K₂ open: E = k · l₁
- K₂ closed: V = k · l₂ (V = E − I r, I = E/(R + r))
- Dividing: r = R (l₁ − l₂) / l₂
Observations
l₁ (open circuit) = —
| R (Ω) | l₂ (cm) | (l₁ − l₂)/l₂ | r = R(l₁−l₂)/l₂ (Ω) |
|---|---|---|---|
| Mean r | — | ||
Check your readings
Graph
Plot (l₁ − l₂)/l₂ against 1/R. This is a straight line through the origin whose slope equals r.
Add at least 2 readings to see the best-fit line.
Precautions
- Connect the positive terminals of the driver cell and the test cell to the same end (A) of the wire.
- The driver cell's emf must be larger than the test cell's, otherwise no balance point exists.
- Keep the key closed only while taking a reading, so the cells do not run down.
- Use a high series resistance with the galvanometer while searching for the balance point, then remove it for the final adjustment.
- Do not slide the jockey along the wire; tap it at each position.